Survey Pro Reference Manual
R-106
Stake Points
The Stake Points screen allows you to stake a
single point or a series of points.
: located at the top of the screen,
accesses the Stakeout Settings screen (Page R-
33).
Design Point
: is the name of the first point that
you want to stake.
Increment
: when advancing to the next point, the
point number is incremented by the value
entered here. (A negative integer can be entered
to have point numbers advance in descending
order.)
: advances the current
Design Point
by the
Increment
value. If that point does not exist and the
Increment
value =1, the
Design Point
is advanced to the next existing point.
Height of Rod
: is the length of the rod.
: accesses the Backsight Setup
screen (Page R-72).
: takes you to the second Stake Points
screen where the
distance and direction to the design point is displayed, see below.