Product Storage Spectra Precision recommends you observe the following
rules for long-term storage (2-3 months). These rules are
dictated by the presence of two non-removable Li-Ion
batteries inside the ProMark 700.
Always charge batteries before long-term storage
Storage room should be ideally at 5°C (41°F) ambient
temperature to minimize irreversible capacity loss.
Always charge batteries after long-term storage.
Power/Data
Connector Pinout
Connector socket type: Hirose HR30-6R-6P
Seen from outside the ProMark 700:
Reset Procedure A reset procedure may be required in some situations where
the ProMark 700 does not operate as expected. No user data
will be lost through this procedure. To trigger a reset
sequence:
Hold the Power button depressed for 12 seconds. Note
that after two seconds of depressing this button, the
ProMark 700 will be turned off or on, depending on the
power status when you started pressing the button. Please
ignore this indication and just keep on pressing the Power
button for the required 12 seconds (starting from the
moment you depressed the button).
After the 12 seconds have elapsed, release the Power
button. The Power/Charging LED starts blinking red and
green, as it would do on a normal start-up, but this time
for about 25 seconds.
At the end of the reset sequence, the ProMark 700 will
stay powered and the Power/Charging LED will turn solid
green.
Pin Signal
1 Ground (power)
2 DC Power In (9-16 V)
3Rx (In)
4 Tx (out)
5 Ground (data)
6 Not connected