Appendix B. Set Command Library
AGB: Enabling/Disabling GLONASS Bias Adjustments
Function This command is used to enable or disable the adjustment of
L1 & L2 GLONASS carrier biases in the receiver so that the
GLONASS Double-Difference carrier residuals between the
receiver and the golden Ashtech receiver are equal to zero
(± noise errors).
MB 500 is considered as the golden Ashtech receiver.
After activating the adjustment function, the receiver name
provided by any message supposed to deliver that name (e.g.
RTCM-3 MT 1033) will appear in the form:
ASHTECH<space><name>
Where <space> is a space character between the two words
and <name> is the receiver name entered through the
$PASHS,RCP,OWN command.
Command Format Syntax
$PASHS,AGB,s1[*cc]
Parameters
Example
Enabling adjustment of GLONASS biases:
$PASHS,AGB,ON*1C
Parameter Description Range Default
s1
Enabling (ON) or disabling (OFF)
adjustment of GLONASS biases
ON, OFF OFF
*cc Optional checksum *00-*FF