216
Set Command Library
Parameters
Example
Setting the PPS signal to a period of 2 seconds, with an offset
of 500 ms and a GPS-synchronized rising edge:
$PASHS,PPS,2,+500,R*74
Relevant Query
Command
$PASHQ,PPS
See Also $PASHS,NME (PTT)
PRT: Setting Baud Rates
Function This command is used to set the baud rate of any of the serial
ports used in the receiver.
Command Format Syntax
$PASHS,PRT,c1,d2[*cc]
Parameters
Parameter Description Range Default
f1
PPS time period, a multiple or
fraction of 1 second.
0: 1 PPS disabled
0 to 1, with 0.1-sec
increments
1 to 60, with 1-sec
increments
0
f2 Time offset in milliseconds. ± 999.9999 0
c3
GPS-synchronized edge code:
“R” for rising edge
“F” for falling edge
R, F R
*cc Optional checksum *00-*FF
Parameter Description Range
c1 Port ID A, D
d2 Baud rate
Port A: 0-15; Port D: 0-9 (see
table below)
*cc Optional checksum *00-*FF
Code Baud Rate
Code
Baud Rate
0 300 7 38400
Seitenansicht 227