252
Set Command Library
Relevant Query
Command
$PASHQ,PAR
USR,POS: Setting Position for User Message Type “GGA”
Function: This function is used to define the position that will be
inserted into the “GGA” user message, as defined through
$PASHS,NME (command run with s1= USR) and
$PASHS,USR,TYP (command run with s= GGA).
Command Format Syntax
$PASHS,USR,POS,m1,c2,m3,c4,f5[*cc]
Parameters
Example
Setting coordinates of position to 37° 22.2912135’ N, 121°
59.7998217’ W, 15.25 m:
$PASHS,USR,POS,3722.2912135,N,12159.7998217,W,15.25
Relevant Query
Command
$PASHQ,USR,POS
See Also $PASHS,NME
$PASHS,USR,TYP
Parameter Description Range
m1
Latitude in degrees and minutes with 7 decimal
places (ddmm.mmmmmmm)
0-90
c2 North (N) or South (S) N, S
m3
Longitude in degrees, minutes with 7 decimal
places (ddmm.mmmmmmm)
0-180
c4 West (W) or East (E) W, E
f5 Height in meters ±0-9999.9999
*cc Optional checksum *00-*FF