Query Command Library
Response Format Syntax
$PASHR,SOM,SNR,d1,d2*cc
Parameters
Example
$PASHQ,SOM,SNR
$PASHR,SOM,SNR,28,28*46
Relevant Set
Command
$PASHS,SOM,SNR
See Also $PASHS,SOM
SOM,WRN: Channel Warnings Mask
Function This command is used to read the current setting of the
channel warnings mask applied to signal observations. This
mask is active only when applying masks to signal
observations has been set to be user defined (see
$PASHS,SOM).
Command Format Syntax
$PASHQ,SOM,WRN[*cc]
Parameters
None.
Response Format Syntax
$PASHR,SOM,WRN,s1,s2*cc
Parameters
Parameter Description Range Default
d1 Mask applied to differential data, in dBHz 0-60 28
d2 Mask applied to raw data, in dBHz 0-60 28
*cc Checksum *00-*FF
Parameter Description Range Default
s1 Mask applied to differential data ON, OFF ON
s2 Mask applied to raw data ON, OFF OFF
*cc Checksum *00-*FF